Lend Lease Tenancy – Barangaroo, NSW

img_5042

Posted October 11, 2016

Barangaroo Tower 3 Lend Lease Tenancy – Levels 8-19

Multi Floor Office Space Protected with Greene Fire Vertical and Horizontal Curtains.

‘The Fire Curtains created more space and provided a great solution Architecturally’ – Mike Harrington Read more…

4 National Circuit, ACT

4 national curcuit 6

Posted May 2, 2016

HORIZONTAL FIRE SEPARATION IN AN ATRIUM NVS™ NO VISIBLE SUPPORTS

By incorporating Coopers FireMaster® NVS™ horizontal fire curtain barriers on levels 2 & 4 the voids are able to be closed in fire mode. This reduces the compartment size to within the BCA requirements for Type A construction of not more than two interconnected floors, a floor area of less than 8,000m2 and office volume less than 48,000m3. Read more…

KING STREET WHARF, NSW

OLYMPUS DIGITAL CAMERA

Posted May 2, 2016

100M LONG ATRIUM. OVER 100 CURTAINS. LARGEST CURTAIN 48M WIDE.

A Coopers SmokeStop smoke curtain system inclusive of side guides (zero edge gaps) was used with bespoke operation and controls to provide a sophisticated level of smoke management. Three different automated alarm scenarios had to be incorporated into a custom fireman’s override panel to meet the objectives of the fire engineer’s design. Read more…

MYER HQ, VIC

myer 12

Posted May 2, 2016

8 FLOOR FEATURE STAIR FIREMASTER® WITH DUAL DROP FOR EGRESS

Coopers FireMaster® vertical fire curtains were used to fire separate every floor from level 2 to 9 providing an FRL of -/120/-. This consisted of both single roller and multiple roller solutions. Read more…

NEW ACTION NISHI, ACT

NISHiiIII

Posted May 2, 2016

ENVIRONMENTALLY FRIENDLY LOW ENERGY NVS™ HORIZONTAL FIRE BARRIERS

With the Department of Climate Change and Energy Efficiency the anchor tenant for this development, achieving an environmentally friendly fire protection plan was a priority for the client. Read more…

Rundle Place, SA

Rundle Place 88

Posted May 2, 2016

PROVEN PERFORMANCE. HOT SMOKE TEST 42M WIDE SMOKESTOP™ ACTIVE SMOKE BARRIER

Coopers Fire SmokeStop™ active smoke barriers were incorporated on all retail levels to separate the mall area into 2 separate zones when activated by general fire alarm (GFA). Each active smoke barrier deploys, at a controlled rate of descent under fail-safe by gravity, to 2.1 meters above finished floor level and therefore creating a baffle at ceiling height of approximately 3 meters in depth. Read more…

The Village Balgowlah, NSW

IMG_0625

Posted April 29, 2016

VII®FIRE FIRE & SMOKE PROTECTION FOR LIFTS

Greene Fire Vii®Fire S active fire curtain barrier is proven to minimize the spread of smoke when tested to AS 1530.7:(2007. Installed across 9 lifts openings over 3 basement levels and thereby greatly minimizing smoke spread from the basement car parks into the shaft to the upper building levels where occupants would potentially be unaware of a fire many levels below them. Read more…

VUE Apartments Act

Vue apartments 43

Posted April 29, 2016

PROPERTY BOUNDARY PROTECTION AS REQUIRED IN BCA CLAUSE C3.4

Coopers FireMaster® Active Fire Curtain Barriers were able to be installed across each opening that was within 3m of the property boundary and will automatically close on any alarm activation in the car park. Read more…

One Shelley Street, NSW

OLYMPUS DIGITAL CAMERA

Posted April 20, 2016

100M LONG ATRIUM. OVER 100 CURTAINS. LARGEST CURTAIN 48M WIDE.

A Coopers SmokeStop smoke curtain system inclusive of side guides (zero edge gaps) was used with bespoke operation and controls to provide a sophisticated level of smoke management. Read more…

Oil Search, NSW

IMG_1216

Posted April 20, 2016

18 SIDED CURVED FIREMASTER® CONCERTINA™ NO SIDE GUIDES

Coopers therefore proposed their revolutionary FireMaster® Concertina™ in a first ever 18 sided polygon arrangement to remove the need for all side guides and columns to provide the full -/120/- fire rating. Read more…